How to Use Self-priming Magnetic Pump for Long-term Stability?

Views : 982
Author : Arthur
Update time : 2022-01-05 15:02:59

Scientific Application Method of Self-priming Magnetic Pump

Preparation before starting:

1. Test whether the rotation direction of the motor is correct (the direction indicated on the self-priming magnetic pump body), and the test time shall be short to avoid dry wear of the internal accessories of the self-priming magnetic pump.
2. Open the exhaust valve to fill the whole self-priming magnetic pump body with a liquid, and close the exhaust valve when it is full.
3. Check whether all parts are normal.
4. The high-temperature type shall be preheated first, and the heating rate shall be 50. C / h to ensure uniform heating of all parts.
Scientific Application Method of Self-priming Magnetic Pump

Start:

1. Close the outlet valve of the self-priming magnetic pump.
2. Fully open the inlet valve of the self-priming magnetic pump.
3. Start the motor and observe whether the self-priming magnetic pump operates correctly.
4. Adjust the opening of the outlet valve to the required working condition. If the user is equipped with a flow meter or pressure gauge at the outlet of the self-priming magnetic pump, the self-priming magnetic pump shall operate at the rated point listed in the performance parameter table by adjusting the opening of the outlet valve. If the user is not equipped with a flow meter or pressure gauge at the outlet of the self-priming magnetic pump, the opening of the outlet valve shall be adjusted; Measure the motor current of the self-priming magnetic pump to make the motor operate within the rated current, otherwise, it will cause the overload operation of the self-priming magnetic pump (i.e. high current operation to burn out the motor). The opening of the outlet valve adjusted correctly is related to the large and small opening and pipeline working conditions.
5. Check the leakage of the shaft seal. Under normal conditions, the leakage of the mechanical seal shall be less than 3 drops/min.
6. Check the motor, and the temperature rise at the bearing is ≤ 80. C。
Scientific Application Method of Self-priming Magnetic Pump

Shutdown:

1. Close the outlet pipeline valve.
2. Stop the motor.
3. Close the inlet and outlet valves.
4. In case of a long-term shutdown, drain the liquid in the self-priming magnetic pump.
The above is the explanation of Dubao Pump Industry on the scientific use of self-priming magnetic pump. Dubao products also include Magnetic Pump, Vertical Pump, Metering Pump, Pneumatic Diaphragm Pump, Stainless Steel Pump, Filter Machine, Filter, etc. if you want to know any more questions, please Contact Us.
Related News
Read More >>
What is a basket filter and how does it work? What is a basket filter and how does it work?
Oct .19.2024
Basket filter is a commonly used filtration equipment, which is mainly used to remove impurities and suspended matter of larger particles in the liquid to protect the normal operation of downstream equipment and systems
How to improve the operation efficiency of chemical magnetic pump? How to improve the operation efficiency of chemical magnetic pump?
Oct .19.2024
Improving the operational efficiency of chemical magnetic pumps can be achieved through a variety of measures, from optimizing operating conditions to regular maintenance, which can effectively improve the overall performance of the pump
What is the maintenance method of plastic magnetic pump? What is the maintenance method of plastic magnetic pump?
Sep .02.2024
The maintenance of plastic magnetic pumps is essential to extend their service life and ensure safe operation. The following are the common maintenance methods of plastic magnetic pump
What is the working principle of plastic magnetic pump? What is the working principle of plastic magnetic pump?
Sep .02.2024
The working principle of plastic magnetic pump is based on magnetic drive and non-leakage structure, mainly including the following key steps