(The case of electroplating filter machine in electroplating production environment)
1. The exhaust valve of the electroplating filter machine is blocked.
Solution: Open the exhaust valve with various practical tools such as boiling water, steam, screwdriver, or electric drill.
2. There is a lack of water in the diaphragm of the electroplating filter machine pressure gauge.
Solution: Remove the pressure gauge, replenish water, put on the raw material belt, and install it.
3. The pressure gauge of the electroplating filter machine is damaged.
Solution: Replace the pressure gauge.
4. The diaphragm of the electroplating filter machine pressure gauge is damaged, and the diaphragm water corrodes the pressure gauge.
Solution: Replace the pressure gauge.
The above are some common questions about Electroplating Filter Machine in the production environment. If you have any questions, please leave us a message.